<LOGO>
FM Transmitter Measurement Report
Created: 2024-08-09 16-50-57
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 55 dBuV SANDELS
Pilot RDS Phase Difference
6.6 kHz 5.6 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
13 kHz 56 kHz 16912 3,6601
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
-0,2 dBr 1,87 dBr 2,9 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 9 --:--
RT
-
AF EON
92.0, 94.7, 98.5, 106.3, 107.5 MHz -
FM Scope Max at: 56 kHz MIN: 13 kHz % above 76 kHz: 3,6601 Acquired: 2024/08/09 16.49.53 Total samples: 16912 Equivalent time: 0:14:05 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200 300 400
FM Scope MAX: 2,9 dBr MIN: -0,2 dBr AVE: 1,87 dBr % above 12,2 dBr: 0,0 Last value: 0,8 dBr (2024/08/09 16.49.53) 16.36 16.38 16.40 16.42 16.44 16.46 16.48 -1 0 1 2 3 Pm [dBr]